Abstract
Laboratory internal quality assurance includes pre-analytic, analytic and post-analytic stages. The error in the pre-analytic reached 68%, 25% in the analytic stage, while in the post-analytic stage it was approximately 14%. The aim of this study to determine the effect of supine position treatment during venous puncture to the total cholesterol level of respondents at minutes 0', 10', 20'and 30'. The method used is a quasi-experimental method. Research subject are 6 STr TLM semester 3 and 5 students using the method sampling by non random sampling. There is a change of -3.2% in the 10th and 20th minutes, there is also a change of -1.6% in the 10th and -30th minutes. Statistical analysis is presented using the one-way ANOVA test, it is said that there are significant differences if the p value <0.05. Result: there was no significant difference on levels total cholesterol (p = 0.068) of respondents who were treated while lying down a venous puncture is performed. Conclusion: there is no significant difference in levels cholesterol of respondents who were treated lying down for 30 minutes at a time a venous puncture is performed.
Downloads
References
- Goswami B, Singh B, Chawla R, and Mallika V. (2010). Evaluation of Error in a Clinical Laboratory: A One- Year Experience. Clinical Chemistry and Laboratory Medicine. ; 48(1): 63-66.
- Kahar H. (2005). Peningkatan Mutu Pemeriksaan di Laboratorium Klinik Rumah Sakit. Indonesian Journal of Clinical Pathology and Medical Laboratory. 12(1): 38-40.
- Rin GD. (2009). Pre-Analytical Workstations: A Tool For Reducing Laboratory Errors. Clinica Chimica Acta. 404(1): 68-74.
- Bonini P, Plebani M, Ceriotti F, and Rubboli F. (2002). Errors in Laboratory Medicine. Clinical Chemistry. 48(5): 691-698.
- Hawkins R. (2012). Managing the Pre- and Post- Analytical Phases of the Total Testing Process. Annals of Laboratory Medicine. 32(1): 5-16
- Rasyid, H. Al, Thoyib, A., Studi, P., Manajemen, M., Sakit R., Kedokteran, F., dan Brawijaya, U. (n.d). Pengaruh Pengetahuan, Sikap, dan Perilaku Perawat tentang Flebotomi terhadap Kualitas Spesimen Laboratorium. 28 (3), 258-262.
- Sanchis-Gomar F, Lippi G. (2014). Phisical activity – an important preanalytical variable. Biochem Med (Zagreb) 24 : 68-79.
- Dixon M, Paterson CR. (1978). Posture and the composition of plasma. Clin Chem 24: 824-826.
- Stoker DJ, Wynn V, Robertson G. (1966). Effect of posture on the plasma cholesterol level. Br Med J 1: 336-338.
- Yoshihisa Shimizu, Kiyoshi Ichihara, Katsunori Kouguchi. (2017). Time required for resetting postural effects on serum constituents in healthy individuals, Clinica Chimica Acta. doi: 10.1016/j.cca.07.022